MPDB66552 FER

Product Details

Manufacturer:
Manufacturer part number:
MPDB66552
CBT Inventory
0
Vendor Inventory
Loading...
CBT - CINCINNATI
0
CBT - SPRINGBORO
0
CBT - SIDNEY
0
CBT - LEXINGTON
0
CBT - LOUISVILLE
0
Availability:
Expected Leadtime 30 days
Estimated dates are contingent upon manufacturer stock.

Description

Brand Name

Mersen

Type

Intermediate Open Style

Description

The next generation power distribution block (PDB). Mersen power distribution blocks provide a safe and easy method of splicing cables, splitting primary power into secondary circuits and fulfilling requirements for fixed junction tap-off points. Unless noted otherwise, all blocks are UL and CSA approved while meeting spacing requirements for feeder and branch circuits in conjunction with UL 508 A and the national electric code. PDB options include single or dual conductor primary inputs and up to 30 secondary outputs. Specialty blocks are available allowing for up to 7 primary inputs.
Mersen Power Distribution Block, Intermediate Open Style, Series: MPDB, 1000 VAC/VDC, 350 A, 2 Pole, 2 Primary Connections/Pole, 15 Secondary Connection/Pole, 14 to 2/0 AWG Wire, 100 kA Short Circuit, Polycarbonate, TiN Coated, 3.57 in L x 4 in W x 2.62 in H Dimensions

Application

Cable Splicing, Splitting Primary Power into Secondary Circuits, Fixed Junction and Tap-Off Point Applications

Standards

CSA Class 6228 01 | RoHS Compliant | UL 1953/File No. E352417

Features

  • Adder poles can be stacked to form multi-pole units in the field without the use of tools, adder poles allow for customization of primary and secondary wire combinations
  • Aluminum connectors accept both AL or CU wire while copper connectors accept CU wire only and all 1-piece tin-plated
  • Insulators are virtually unbreakable, made of glass-filled polycarbonate, see-through hinged safety covers are optional and provide a greater deg of safety and shock resistance where required, hinged covers can be installed without tools
  • 1 in through air and 2 in over surface between uninsulated live parts of opposite polarity meets requirements for feeder and branch circuit applications of UL508A
  • Polycarbonate safety covers provide dead-front protection
  • Each cover has a test probe hole in the center for circuit checking
  • Tin-plated copper contact

Specifications

Amperage Rating:350 A
Country of Origin:MX
Dimensions:3.57 in L x 4 in W x 2.62 in H
Finish:TiN Coated
Material:Polycarbonate
Number of Poles:2
Primary Connections/Pole:2
Secondary Connection/Pole:15
Series:MPDB
Short Circuit Current Rating:100 kA
Voltage Rating:1000 VAC/VDC