Brand Name

ProSoft Technology

Description

The SlotServer ControlLogix BACnet communication Interfaces allow an Allen Bradley ControlLogix platform to pass up to 1500 points of data between a ControlLogix PAC and BACnet devices and networks. The BACnet SlotServer can be configured as a BACnet slave or master enabling exchange of information between BACnet master devices such as Trane BCU, Alerton controllers, etc) or BACnet slave devices such as VSD, lighting controls, AC controls, etc. Physically configured to plug into a standard ControlLogix rack, the SlotServer module is configured for the 1756 platform using standard RSLogix message block reads to allow for efficient transfer of large blocks of data. Specific configuration data is contained in the configuration CSV file downloaded to the module. SlotServer is a flexible communications module that can be configured to communicate to a wide range of protocols found in the extensive fieldserver technologies library of protocols. The SlotServer is recognized as an input/output module by ControlLogix and has access to processor memory for data transfer between processor and module
ProSoft Technology Communication Interface Module, 0 to 60 deg C, 600 mA at 5 V Back Plane Current Load, 5.11 in H x 3.7 in H x 2.27 in D

Application

For building automation use

Standards

TUV Rheinland | CE Certified | ISO 9001

Features

  • Module status, backplane transfer status, communications status, configuration error, system error, serial activity, EtherNet activity, 10/100 base-T indicator LED indicators
  • TP/FT-10 (lonworks), RS-485 (2-wire), EtherNet (10/100 baseT) connections
  • For lonworks commissioning service pin
  • Local or remote rack mounting
  • Configuration data is contained in the configuration csv file downloaded to the module, sample configuration file is included, configuration file development service available from fieldserver technologies or approved system integrators configuration
  • Up to 95% relative humidity, with no condensation humidity
  • SlotServer is a flexible communications module that can be configured to communicate to a wide range of protocols found in the extensive fieldserver technologies library of protocols
  • The SlotServer is recognized as an input/output module by ControlLogix and has access to processor memory for data transfer between processor and module

Specifications

Dimensions:5.11 in H x 3.7 in H x 2.27 in D
Specifications:600 mA at 5 V Back Plane Current Load
Temperature Rating:0 to 60 deg C

Resources